DACHS – Technical Information
A brief summary of technical aspects of the DACHS is provided below, with downloadable
Data Sheets for each fuel option available.
- Prime Mover: Single cylinder internal combustion engine
- Available Fuel Types: Natural gas and LPG
- Gross Electrical Outputs: 5.5 kWe (natural gas/LPG units)
- Electrical Output: 400V, 3 phase, 50HZ
- Electrical Connection: Grid parallel operation
- Heat Outputs: 12.5 kWth (natural gas/LPG units)
- Exhaust Condenser: Up to 3.0 kWth additional heat output (subject to water circuit return
temperature)
- Heating Medium: Low temperature hot water
- Fuel Input: 22.8 kW (natural gas/LPG units).
Higher Heating Value / Gross Calorific Value
- Dimensions: 720mm (W) x 1070mm (D) x 1000mm (H)
- Weight: 530 kg
- Services Intervals: 3,500 running hours (natural gas/LPG units)